DSpace Repository

Dijital mamografi cihazlarının kalite kontrol, kalibrasyon ve standardizasyonu

Show simple item record

dc.contributor.author Ayrancıoğlu , Oğuzhan
dc.date.accessioned 2015-11-25T14:31:04Z NULL
dc.date.available 2015-11-25T14:31:04Z NULL
dc.date.issued 2011
dc.identifier.uri http://hdl.handle.net/20.500.12397/9941 NULL
dc.description.abstract Bu çalışmanın amacı, ülkemizdeki dijital mamografi sistemlerinde (FFDM) kalite kontrol testlerinin standardizasyonu yapılırken, mamografik görüntü kalitesi ve meme dozu arasındaki ilişkinin ortaya konulmasıdır.Dijital mamografi cihazları için kalite kontrol testleri düzenlendi ve uygulanabilme performansı ve önemine göre optimize edildi. Testlerde cihaz, x-ışını üretimi, kompresyon ve kolimasyon, görüntü alıcı sistem, dozimetri, görüntü gösterimi olarak beş bölümde değerlendirildi. X-ışını üretiminin performası farklı kV ve mAs değerlerinde test edildi. Tüp çıkış değeri "51-89 μGy/mAs" olarak bulundu. Tüpteki radyasyon kaçağı değeri ölçüldü ve X-ışını kalitesi için yarı değer kalınlıkları sırasıyla; 0,248mm, 0,259mm, 0,267mm, 0,272mm, 0,276mm alüminyum (Al) olarak hesaplandı. Kaynak - görüntü mesafesi 66,6cm olarak ölçüldü. Otomatik ışınlama kontrolünün performansı değerlendirildi. Kompresyon değerlendirmesinde göğüs tablasının sıkıştırma kuvveti 158,6N olarak ölçüldü. Kolimasyon değerlendirmesinde ise göğüs tablasının x-ışını alanına olan hizası ile hem ışık alanının hemde detektör alanının x-ışını alanına olan hizası kontrol edildi. X-ışını alanı ile ışık alanı arasında sağ ve sol kenarlarda %2yi geçkin sapma ölçüldü. X-ışını alanı ile detektör alanı arasında ise sadece ön kenarda sapma olduğu görüldü. Görüntü alıcı sistem ile ilgili olarak, detektör sisteminin çalışma sınırlarına bakıldı ve yanıt fonksiyonu değerlendirildi. Uzaysal çözünürlük kullanılan test paterni ile ölçüldü, anot - katot eksenine paralel iken milimetre de 12 - 14 çizgi çifti görülebilirken eksene dik yönde 11 çizgi çifti görüldü. Detektörün CNR değeri sayısal olarak 1,67 bulundu. Bunun yanı sıra SNR ve FOM değerleri sırasıyla; 8,138, 7,927, 6,425 ve 13697, 4640, 1331 bulundu. Artefakt ölçümlerinde detektörden kaynaklanan herhangi bir artefakta rastlanmadı. Monitör sistemlerinin değerlendirmesi testleri düzenlemesine rağmen elde olmayan sebeplerden ötürü gerçekleştirelemedi.Sonuç olarak dijital mamografi cihazı üzerinde uygulanan testler literatür ile karşılaştırıldı. Gerçekleştirilme olasılığı ve önemine göre derlenen testlerin sonuçları değerlendirildi. Testler gerçekleştirme periyotlarına göre derlendi. Bu çalışmanın, ülkemiz dijital mamografi akrediyasyon programını oluşturmak açısından referans bir kaynak olacağı düşünülmektedir. In the present study, it was aimed to evaluate working performance of digital mammography systems (FFDM) within the scope of quality control tests.Quality control tests for digital mammography devices were designed and optimized according to applicability performance and importance. For the tests, the device divided into five parts as X ray generation, compression, image receptor system, dosimetry and image display. The performance of x ray generation was tested with different kV and mAs values. Tube output value was confirmed as "51-89 μGy/mAs". The radiation leakage in tube was measured and for the X ray quality, half-value layers were calculated as 0.248mm, 0.259mm, 0.267mm, 0.272mm, 0.276mm aluminum (Al), respectively. The source - image distance was measured as 66.6cm. The performance of automatic teleportation control was evaluated. The compression force of the breast tray was calculated and found as 158.6N. The level of breast tray to the X ray area and the level of both light area and detector area to the X ray area were controlled. More than 2% deviation was measured in the left and right edges between the x ray area and detector area. The working range of the detector system about the image receptor system was examined and the response function was evaluated. Spatial resolution was measured with the current test pattern, when the test pattern was parallel to the anode - cathode axis, 12 - 14 line pairs per millimeter were determined. But when it was perpendicular to the axis, 11 line pair was seen. The CNR value of the detector was found as 1.67 numerically. The calculated SNR and Fom values were found as 8.138, 7.927, 6.425 and 13697, 4640, 1331 respectively. In artifact measurements, no artifact arising from the detector was seen. The tests for the evaluation of the monitor systems could not be carried out due to the reasons beyond control. Finally, the tests carried out on the digital mammography device were compared with the literature. The results of the tests which were compiled according to the probability and importance of realization were evaluated. The tests were compiled according to their realization periods. And it was aimed to present a reference of resource in terms of creating the digital mammography accreditation program of our country. en_US
dc.language.iso tr en_US
dc.publisher DEÜ Sağlık Bilimleri Enstitüsü en_US
dc.subject en_US
dc.title Dijital mamografi cihazlarının kalite kontrol, kalibrasyon ve standardizasyonu en_US
dc.title.alternative Quality control, calibration and standardization of full field digital mammography systems en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account