DSpace Repository

T1-4 N0-3 M0 oral kavite kanserlerinde sentinel lenf nodunun saptanmasında lenfosintigrafi ve dual faz F-18 FDG PET-BT'nin tanısal değeri

Show simple item record

dc.contributor.author SÜRÜCÜ, ERDEM
dc.date.accessioned 2015-11-27T16:28:21Z NULL
dc.date.available 2015-11-27T16:28:21Z NULL
dc.date.issued 2011
dc.identifier.uri http://hdl.handle.net/20.500.12397/13039 NULL
dc.description.abstract Amaç: Bu çalışmada oral kavite kanserli hastalarda primer tümör alanının ve lenfatik metastazların değerlendirilmesinde dual faz F-18 FDG PET-BT'in tanısal rolü, sentinel lenf nodunun (SLN) saptanması, F-18 FDG PET-BT ile metastatik lenf nodlarının saptanabilirliğinin bölgesel farklılıkları, primer tümör alanındaki F-18 FDG tutulum miktarı ile lenf nodu metastazı arasındaki ilişki, konvansiyonel görüntüleme yöntemleri ile karşılaştırıldığında F-18 FDG PET-BT ve sentinel lenf nodu biyopsisinin (SLNB) tedavi yaklaşımında değişikliğe yol açıp açmadığı araştırıldı. Yöntem: Bu retrospektif çalışmaya 16 hasta (4 kadın; 12 erkek, yaş aralığı, 29-81 yaş) dahil edildi. 16 hastaya operasyon öncesi F-18 FDG PET-BT ve operasyondan 2 saat önce lenfosintigrafi yapıldı. F-18 FDG enjeksiyonundan 1 (erken) ve 2 saat (geç) sonra F-18 FDG PET-BT görüntüleri elde edildi. Tanısal BT veya MR görüntüleri radyoloji uzmanı tarafından değerlendirildi. PET/BT görüntülerinde lenf nodunda malignite yorumu 3 kritere göre değerlendirildi. 1: Görsel olarak, 2: Tümör/komşu kas dokusu SUVmax (T/M) oranı, 3: Tümör boyutuna göre düzeltilmiş SUVmax değerleri. Bu üç kriter için 1. ve 2. saat çekimler alınarak ayrı ayrı değerlendirme yapıldı. Operasyon sonrası histopatolojik değerlendirme boyun seviyelerine göre kaydedildi. Ayrıca lenf nodlarında erken görüntülerde tümör/karaciğer SUVmax oranına (T/Kc) bakıldı, SUVmax değeri, T/M ve T/Kc oranlarında malignite için cut off değerleri araştırıldı. Bulgular: Histopatolojik sonuçlar ile 5 hastada boyunda metastatik lenf nodları saptanırken (N+), 11 hastada lenf nodu metastazı saptanmadı (N-). F-18 FDG PET-BT'nin BT'sinde 43 lenf nodundan 14 tanesi malign, 29 tanesi benign olarak değerlendirildi. N(+) ve N(-) hastalar arasında yaş, tümör derinliği ve mitoz sayısı için fark bulunmazken primer tümör alanı için erken ve geç SUVmax değerleri arasında anlamlı değişiklik saptandı (P=0,011). Görsel olarak malign olarak değerlendirilen lenf nodlarının ortalama SUVmax değeri, T/M oranı ve T/Kc değeri sırasıyla erken çekimde ortalama 7,67±4,95, 7,10±3,18, 2,85±1,83 iken geç çekimde SUVmax değeri ve T/M oranı 8,0±5,68 ve 9,08±4,31; benign olarak değerlendirilen lenf nodlarının erken çekimde ortalama SUVmax değeri, T/M oranı ve T/Kc değeri 1,69±0,43, 1,49±0,48 ve 0,59±0,22 iken geç çekimde SUVmax değeri ve T/M oranı 1,66±0,36 ve 1,66±0,69 olarak saptandı. Histopatolijik metastatik lenf nodu saptanan bölgelerdeki lenf nodlarının erken ve geç çekim arasında SUVmax değeri için (p=0.00) ve T/m oranı için (p=0.01) anlamlı fark saptanırken, benign lenf nodları için anlamlı değişiklik saptanmadı. En yüksek sensitivite, spesifisite, NPV ve PPV değerler T/M oranına göre hem erken hem de geç çekimler için elde edildi. ROC analizi sonucunda benign-malign lenf nodu ayrımında erken çekimde SUVmax 3,4 ve T/m oranı 3,2 eşik değeri için; geç çekimde SUVmax 4,0 ve T/m oranı 3,8 eşik değeri için sensitivite % 93, spesifisite % 96 olarak saptandı. T/Kc oranı için 1 eşik değeri için sensitivite ve spesifisite % 93 olarak saptanmıştır. Lenfosintigrafi ile 40 adet, gama probe ile 31 adet sentinel lenf noduna ait olabilecek aktivite tutulumu saptandı. N(+)hastalığı olan 5 hastada 32 adet metastatik lenf nodu saptandı. 3 hastada lenfosintigrafi ve gama probe ile saptanan 5 adet lenf nodunda metastaz saptandı. SLNB'si metastaz açısından pozitif olan 5 lenf nodunun 2'sinde Hematoksilen-Eozin boyaması (H&E) ile metastaz saptanırken, 3'ünde immunohistokimya ile metastatik odak saptanmıştır. SLNB 2 hastada yanlış negatif olarak saptandı. SLNB ile yanlış değerlendirilen iki hastada skip metastazlar F-18 FDG ile saptandı. SLNB ile metastaz saptanan F-18 FDG PET-BT'de atlanan lenf nodu metastazı saptanmadı. Sonuç: F-18 FDG PET/BT oral kavite kanserlerinde boyun evrelemesinde tanı değerini güçlendiren, skip LN metastazlarını yakalayabilen bir modalite olarak değerlendirilebilir. Çalışmamızda geç çekimlerin LN metastazlarının degerlendirilmesinde sensitivite ve spesifisiteyi düşürdüğünü saptadık. Ayrıca N(+) ve N(-) hastalar arasında primer tümör maksimum derinlikleri ve primer tümördeki mitoz sayısı arasında anlamlı bir fark bulunmamasına rağmen N(+) hastalarda primer tümör alanındaki F-18 FDG tutulumu N(-) hastalara göre anlamlı şekilde daha yüksek olarak tespit edildi. Bu bulgu ile SUVmax yüksekliğinin tümör agresifliğini bağımsız bir faktör olarak gösterdiği ve N(+) hastalığı öngördüğü söylenebilir. Çalışmamızda tespit edilen eşik değerleri malign ve benign lenf nodlarını ayırt etmekte yüksek ayırım gücüne sahip eşik değerler olarak kabul edilebilir. T/M oranı lenf nodunda malignite değerlendirilmesinde en yüksek tanı değerine sahip krıter olarak saptandı. Ancak, hasta sayısının fazla olduğu çalışmalar gerekmektedir.   Aim: Our objective was to evaluate the diagnostic role of F-18 FDG PET-CT in the patients with oral cavity cancer. We also investigated the diagnostic accuracy of the lymphoscintigraphy for the detection of sentinel lymph node (SLN) in the patients with oral cavity cancer. In terms of the diagnostic role of F-18 FDG PET-CT, we investigated the F-18 FDG uptake difference in metastatic lymph nodes according to regional neck levels, the correlation between F-18 FDG uptake in the primary tumor and lymph node metastases, comparison with the conventional imaging methods, and cutoff values for detection of malignant lesions, and the additional diagnostic value of dual phase imaging.We also searched that the impact of F-18 FDG PET-CT and sentinel lymph node biopsy (SLNB) together in decision making of the patients with oral cavity cancer. Methods: 16 patients (4 female; 12 male, age range, 29-81 years) were included in this retrospective study. F-18 FDG PET-CT and lymphoscintigraphy (2 hours before the surgery) were performed for all the patients before surgery. PET-CT scans were performed one (early) and two hours (delayed) after injection 8-12mCi (296-444 MBq) of F-18 FDG. Diagnostic CT or MR was evaluated by an experienced radiologist on head and neck radiology. In the PET-CT, malignancy in the lymph nodes was evaluated according to 3 criteria: 1: Visual assessment 2: The ratio of SUVmax in tumor/ adjacent muscle tissue (T/M), 3: SUVmax adjusting to the size of lymph nodes. The evaluation of malignancy in the lymph nodes was done separately for early and delay scans. The histopathological evaluation of the surgey was recorded according to the neck levels. Furthermore, the ratio of SUVmax in tumor/liver uptake (T/L) in the lymph nodes was calculated. The sensitivity, specificity, negative (NPV) and positive predictive values (PPV) in F-18 FDG PET-CT for early and delay scans were calculated for each malignancy criteria expect T/L. T/L ratios were calculated just for early images. ROC curves were obtained for SUVmax, T/M and T/Kc. The threshold values were calculated in the terms of highest sensitivity and specificity points. Results: Histopathological evaluations revealed 5 patients had metastatic lymph nodes (N+) whereas 11 patients had benign lymph nodes (N-). 14 of 43 lymph nodes that were visualized in CT of F-18 FDG PET-CT were evaluated as malignant whereas 29 of 43 lymph nodes were evaluated as benign. There was no statistical difference between the N(+) ve N(-) patients in the terms of age, depth of primary tumor and the number of mitosis. However, there was significant difference in the terms of early and delay F-18 FDG uptake of primary tumors between the N(+) ve N(-) patients (P=0,011). The average of SUVmax, T/M and T/L ratios of visually malignant lymph nodes were 7,67±4,95, 7,10±3,18, 2,85±1,83 in early scan respectively. The average of SUVmax and T/M ratio were 8,0±5,68 and 9,08±4,31 in delay scan. The average of SUVmax, T/M and T/Kc ratios of visually benign lymph nodes were 1,69±0,43, 1,49±0,48 ve 0,59±0,22 respectively in early scan. The average of SUVmax and T/M ratios were 1,66±0,36 and 1,66±0,69 in delay scan. There was significant difference in the value of SUVmax (p=0.00) and in the T/M ratios (p=0.01) between early and delay scans for the lymph nodes. There was no statistical difference in the value of SUVmax and T/M ratios between early and delay scans for the benign lymph nodes. The highest sensitivity, specificity, NPV and PPV were obtained in the criteria of T/M ratios for both early and delay scan. With the treshold value of early SUVmax as 3,4 and early T/M ratio as 3,2; delay SUVmax as 4,0 and delay T/M ratios as 3,8 which is obtained from our population using ROC curve, 93% sensitivity, 96% specificity were calculated. With the treshold value of T/L ratios as 1,0 we found 93% sensitivity and specificity. 40 lymph nodes were displayed with lymphoscintigraphy, 31 lymph nodes were detected with gama probe. There were 32 metastatic lymph nodes in 5 N(+) patients. 5 lymph nodes were detected with lymphoscintigraphy and gama probe in 3 patients. Metastasis were proven with hematoxylin-eosin (H&E) in 2 of 5 metastatic lymph nodes and metastatis were proven with immunohistochemistry in 3 of 5 metastatic lymph nodes. SLNB was false negative in 2 patients. F-18 FDG showed skip lymp node metastases in these SLNB negative patients. Conclusion: This study indicates that F-18 FDG PET-CT is a reliable method for the correct evaluation of primary tumor and N staging in oral cavity cancers. It might catch skip metastasis in lymph nodes which can be missed with SLNB. We found that delay scans may cause to decrease the sensitivity and specificity in our study. In addition, since there was significant difference in the terms of early and delay F-18 FDG uptake of primary tumors between the N(+) ve N(-) patients, FDG uptake in primary tumor might be an independent factor showing the aggressivity of primary tumor and might predict N(+) disease. This study showed that T/M ratios in the lymph nodes can be used to evaluate malignancy with a high diagnostic accuracy. The further studies with the high number of patients are needed. en_US
dc.language.iso tr en_US
dc.publisher Dokuz Eylül Üniversitesi Tıp Fakültesi en_US
dc.subject en_US
dc.title T1-4 N0-3 M0 oral kavite kanserlerinde sentinel lenf nodunun saptanmasında lenfosintigrafi ve dual faz F-18 FDG PET-BT'nin tanısal değeri en_US
dc.title.alternative The diagnostic role of Dual phase F-18 FDG PET-CT and lymphoscintigraphy for the detection of sentinel lymph node in the patients with T1-4 N0-3 M0 oral cavity cancers en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account