DSpace Repository

Aortik biyoprostetik kalp kapaklarının orta dönem izlem sonuçları: Retrospektif klinik çalışma

Show simple item record

dc.contributor.author BAL, MELİH
dc.date.accessioned 2015-11-27T16:19:41Z NULL
dc.date.available 2015-11-27T16:19:41Z NULL
dc.date.issued 2013
dc.identifier.uri http://hdl.handle.net/20.500.12397/12893 NULL
dc.description.abstract Çalışmamızda Eylül 2008 - Ağustos 2012 tarihleri arasında, aortik pozisyonda biyoprotez implantasyonu uygulanmış olan 32 hastanın yaş, cinsiyet, vücut yüzey alanı (body surface area = BSA), tercih edilen kapak boyutu, etkin kapak alan indeksi (effective orifice area index = iEOA), preoperatif tanı değişkenleri ile postoperatif takipte ölüm, reoperasyonlar ve transaortik gradyent verileri karşılaştırmalı analizlerle değerlendirilmiştir. Çalışmaya katılan 32 hastanın 19?unda ekokardiyografi (EKO) verilerine ulaşılabildi ve ortalama aort gradyenti 25mmHg olarak hesaplandı. Takip sürecinde 9 hasta kaybedildi ve 2 hastaya reoperasyon uygulandı. Reoperasyon uygulanan hastalardan da 1 tanesi postoperatif erken dönemde kaybedildi. Çalışma sonlandırıldığında reoperasyonsuz sağkalım oranı %68,8 idi. Ortalama takip süresi 363 gün, en kısa takip süresi 129 gün, en uzun takip süresi 1339 gün olmuştur. Bir yıllık sağkalım %83,8, iki yıllık sağkalım ise %67,5-75 olarak hesaplanmıştır. Çalışmamızda iEOA>0,85 olmasının, büyük ebatta kapak tercihinin, BSA?nın küçük olmasının sağkalıma olumlu etkisi olmadığını, yaş cinsiyet ve preoperatif tanı kriterlerinin de sağkalımı etkilemediğini saptadık. Thirtytwo cases who underwent bioprosthetic aortic valve replacement between September 2008 and August 2012 are included in this study. Relationship between reoperation rate, survival, mortality and age, gender, body surface area (BSA), effective orifice area index (iEOA), preoperative diagnosis and postoperative follow-up variables have been investigated. In our study, 32 patients who underwent implantation of bioprosthetic valve at aortic position between the dates of September 2008 - August 2012, were evaluated and analysed comperatively by age, gender, BSA, preferred valve size, iEOA, preoperative diagnosis and postoperative follow-up variables, mortality, reoperations and transvalvular gradient. Echocardiographic data were available for 19 of 32 patients participated in the study and mean aortic gradient was calculated as 25mmHg. Nine patients died during follow-up, and 2 patients underwent reoperation, and one of them died in the early postoperative period. Reoperation-free survival rate was 68.8% at the end of the study. Average follow-up period was 363 days (±129-1339). One-year survival rate was 83.8%, and two-year survival was between 67,5% to 75%. We have found no significant effect of iEOA> 0.85, bigger valve size and smaller BSA on survival rate. Age, sex and pre-operative diagnostic criteria also had no effect on survival rate. en_US
dc.language.iso tr en_US
dc.publisher Dokuz Eylül Üniversitesi Tıp Fakültesi en_US
dc.subject en_US
dc.title Aortik biyoprostetik kalp kapaklarının orta dönem izlem sonuçları: Retrospektif klinik çalışma en_US
dc.title.alternative Midterm follow-up results of bioprosthetic aortic heart valves: Retrospective clinical trial en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account